Gear Motor Electromagnetic DC Motor DC Motor for Gantry Planer

Product Details
Customization: Available
Application: Universal, Industrial, Household Appliances, Car, Power Tools
Operating Speed: High Speed
Manufacturer/Factory, Trading Company
Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Management System Certification
ISO 9001, ISO 14000
  • Gear Motor Electromagnetic DC Motor DC Motor for Gantry Planer
  • Gear Motor Electromagnetic DC Motor DC Motor for Gantry Planer
  • Gear Motor Electromagnetic DC Motor DC Motor for Gantry Planer
  • Gear Motor Electromagnetic DC Motor DC Motor for Gantry Planer
  • Gear Motor Electromagnetic DC Motor DC Motor for Gantry Planer
  • Gear Motor Electromagnetic DC Motor DC Motor for Gantry Planer
Find Similar Products

Basic Info.

Model NO.
DC Motor
Excitation Mode
Compound
Function
Control, Driving
Casing Protection
Closed Type
Number of Poles
8
Structure and Working Principle
Brushless
Type
Z4
Certification
ISO9001, CCC
Brand
Semc
Product Name
DC Motor
Motor Type
DC Motor,Acmotor,Stepper Motor,Asynchronous Motor
Power
60~2800kw
Voltage
220~1000V
Transport Package
Plywood
Specification
international standard
Trademark
SEMC
Origin
China
HS Code
8501320000
Production Capacity
10000/Year

Product Description


Product Description:
 
DC motor is a rotating motor that can convert DC electric energy into mechanical energy (DC motor) or mechanical energy into DC electric energy (DC generator). It is a motor that can convert DC and mechanical energy into one another. When it runs as a motor, it is a direct current motor, which converts electrical energy into mechanical energy; when it runs as a generator, it is a direct current generator, which converts mechanical energy into electrical energy.

 
Product Name Gear Motor Electromagnetic DC Motor DC Motor for gantry planer
Motor Type DC Motor,ACMotor,Stepper Motor,Asynchronous Motor ,Synchronous Motor
(Electric machinery)
Composition structure The structure of DC motor should consist of two parts: stator and rotor. The static part of DC motor is called stator. The main function of stator is to generate magnetic field, which is composed of base, main magnetic pole, commutation pole, end cap, bearing and brush device. Running part is called rotor, whose main function is to generate electromagnetic torque and inductive electromotive force. It is the hub of energy conversion of DC motor. So it is also commonly called armature, which consists of rotor, armature core, armature winding, commutator and fan.
Model Z Type
Seat number Z315-Z1000
power 60~2800kW
Voltage 220~1000V
Torque range 1.5 ~180kNm
Protection level IP23, IP44
Cooling mode IC06,IC17,IC37,IC81W
Operating speed  Constant Speed /Low Speed /Adjust Speed /High Speed Other 
Main classification DC Motor is a machine that converts mechanical energy into DC power. It is mainly used as DC motor for DC motor, electrolysis, electroplating, smelting, charging and excitation power supply of alternator. Although in places where DC power is needed, AC power rectifier is also used to convert AC into DC power, but from some aspects of performance, AC rectifier power supply can not completely replace DC generator.  
Application DC motors are widely used in tape recorders, video recorders, video discs, electric shavers, hair dryers, electronic watches, toys and so on.
Maintenance method Professional motor maintenance center motor maintenance process: cleaning stator and rotor - replacing carbon brush or other parts - vacuum F pressure dipping paint - drying - Calibration balance.
1. Use environment should be always dry, motor surface should be kept clean, air intake should not be hindered by dust, fibers and other obstacles.
2. When the thermal protection of the motor continues to operate, it should be ascertained whether the fault comes from the motor or the overload or the setting value of the protective device is too low. After eliminating the fault, it can be put into operation.
3, ensure that the motor is well lubricated during operation. The general motor runs for about 5000 hours, that is to say, lubricating grease should be added or replaced. When bearing overheating or lubricating deterioration is found in operation, the hydraulic pressure should change lubricating grease in time. When replacing grease, the old grease should be removed, and the oil groove of bearing and bearing cover should be washed with gasoline. Then ZL-3 lithium grease should be filled with 1/2 (2 poles) and 2/3 (4 poles, 6 poles and 8 poles) of the cavity between the inner and outer rings of the bearing.
4. When the life of the bearing is over, the vibration and noise of the motor will increase obviously. When the radial clearance of the bearing reaches the following value, the bearing should be replaced.
5, when removing the motor, it is OK to remove the rotor from the shaft extension or the non extension end. If it is not necessary to unload the fan, it is more convenient to take out the rotor from the non-axle extension end. When pulling out the rotor from the stator, the stator winding or insulation should be prevented from being damaged.
6. When replacing the windings, the form, size, turns and gauges of the original windings must be recorded. When these data are lost, they should be obtained from the manufacturer and the original designed windings should be changed at will, which often deteriorates one or several performance of the motor or even makes it impossible to use them.
 


Gear Motor Electromagnetic DC Motor DC Motor for Gantry Planer







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier