Customization: | Available |
---|---|
Type: | Roller Crusher |
Motor Type: | AC Motor |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SEMC is the leading brand of global industry .
You are our very important customer, please do not hesitate to send any question!
Induction furnace is used for smelting or insulating ferrous metals, non-ferrous metals, sponge iron, such as scrap iron, scrap steel, copper, aluminum and so on. Complete working equipment such as continuous casting machine, rolling mill, mainly used for the production of billet, steel bar, angle steel, H-beam, I-beam, etc. Using KGPS, IGBT, single or double power supply technology, PLC (Siemens) can be realized throughout the monitoring.
Main supply list: 2 sets of electric furnace body, 2 sets of hydraulic or mechanical tilting electric furnace mechanism, 1 set of control platform, 1 set of intermediate frequency control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), low voltage control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), 1 set of capacitor cabinet, 4 or 8 water-cooled cables; 1 water temperature alarm, 1 leakage alarm; 1 crucible mold, 1 liquid One batch of pressure steel pipe, one set of copper row, three water tanks. Transformer, cooling tower, furnace builder, furnace lining ejector, furnace cover.
KGSP Induction Electric Furnace
GW-8-4000-0.5J KGSP Induction Electric Furnace
GW-1-750-1JJ Medium frequency coreless electric furnace
GW-50-22000-0.2J No induction melting furnace
GW-0.25-160-1JJ melting electric furnace
GW-1.5-1000-1J Medium frequency induction furnace
NO. | Electric Furnace Type |
Input power (KW) |
input voltage (V) |
Input current (A) |
Rated power (KW) |
DC current (A) |
DC voltage (V) |
Melting rate (T/H) |
working frequency (HZ) |
working voltage (V) |
cooling water pressure(MPA) |
Rated capacity (T) |
Power consumption (KWH/T) |
|
Power Supply |
Furnace body |
|||||||||||||
1 | GW-0.25-160/1JJ | 180 | 380 (6 Pulse) |
256 | 160 | 320 | 500 | 0.24 | 1000 | 750 | 0.1~0.15 | 0.25~0.3 | 0.25 | 790 |
2 | GW-0.5-250/1JJ | 280 | 380 (6 Pulse) |
400 | 250 | 500 | 500 | 0.4 | 1000 | 1500 | 0.1~0.15 | 0.25~0.3 | 0.5 | 770 |
3 | GW-0.5-250/1J | 280 | 380 (6 Pulse) |
400 | 250 | 500 | 500 | 0.4 | 1000 | 1500 | 0.1~0.15 | 0.25~0.3 | 0.5 | 770 |
4 | GW-0.75-400/1JJ | 400 | 380 (6 Pulse) |
650 | 400 | 800 | 500 | 0.6 | 1000 | 1500 | 0.1~0.15 | 0.25~0.3 | 0.75 | 770 |
5 | GW-0.75-400/1J | 400 | 380 (6 Pulse) |
650 | 400 | 800 | 500 | 0.6 | 1000 | 1500 | 0.1~0.15 | 0.25~0.3 | 0.75 | 770 |
6 | GW-1-500/1JJ | 550 | 380 (6 Pulse) |
800 | 500 | 1000 | 500 | 0.8 | 1000 | 1500 | 0.1~0.15 | 0.25~0.3 | 1 | 750 |
7 | GW-1-750/1JJ | 800 | 380/690 (6 Pulse) |
1200/ 700 |
750 | 1500/ 850 |
500/ 880 |
0.9 | 1000/ 500 |
1500/ 2600 |
0.1~0.15 | 0.25~0.3 | 1 | 720/660 |
8 | GW-1-750/1J | 800 | 380/690 (6 Pulse) |
1200/ 700 |
750 | 1500/ 850 |
500/ 880 |
0.9 | 1000/ 500 |
1500/ 2600 |
0.1~0.15 | 0.25~0.3 | 1 | 720/660 |
9 | GW-1.5-1000/0.5JJ | 1100 | 690 (6 Pulse) |
912 | 1000 | 1140 | 880 | 1.2 | 500 | 2600 | 0.1~0.15 | 0.25~0.3 | 1.5 | 700 |
10 | GW-1.5-1000/0.5J | 1100 | 690 (6 Pulse) |
912 | 1000 | 1140 | 880 | 1.2 | 500 | 2600 | 0.1~0.15 | 0.25~0.3 | 1.5 | 700 |
11 | GW-2-1500/0.5JJ | 1650 | 690 (6 Pulse) |
1360 | 1500 | 1700 | 880 | 1.7 | 500 | 2600 | 0.1~0.15 | 0.25~0.3 | 2 | 675 |
12 | GW-2-1500/0.5J | 1650 | 690 (6 Pulse) |
1360 | 1500 | 1700 | 880 | 1.7 | 500 | 2600 | 0.1~0.15 | 0.25~0.3 | 2 | 675 |
13 | GW-2-2000/0.5JJ | 2200 | 690 (6 Pulse) |
1400 | 2000 | 2275 | 880 | 1.9 | 500 | 2600 | 0.1~0.15 | 0.25~0.3 | 2 | 650 |
14 | GW-3-2500/0.5JJ | 2750 | 690/950 (6 Pulse) |
2275/ 1700 |
2500 | 2840/ 2080 |
880/ 1250 |
2.56 | 500 | 2600/3200 | 0.1~0.15 | 0.25~0.3 | 3 | 610/560 |
15 | GW-3-2500/0.5J | 2750 | 690/950 (6 Pulse) |
2275/ 1700 |
2500 | 2840/ 2080 |
880/ 1250 |
2.56 | 500 | 2600/3200 | 0.1~0.15 | 0.25~0.3 | 3 | 610/560 |
16 | GW-4-3000/0.5J | 3300 | 690/950 (6 Pulse) |
2730/ 2040 |
3000 | 3410/ 2500 |
880/ 1250 |
3.2 | 500 | 2600/3200 | 0.1~0.15 | 0.25~0.3 | 4 | 610/560 |
17 | GW-5-4000/0.5J | 4400 | 950 (6 Pulse) |
2300 | 4000 | 3330 | 1250 | 5 | 500 | 3400 | 0.1~0.15 | 0.25~0.3 | 5 | 600/550 |
18 | GW-6-4000/0.5J | 4400 | 950 (12 Pulse) |
2300 | 4000 | 3330 | 1250 | 5 | 500 | 3400 | 0.1~0.15 | 0.25~0.3 | 6 | 600/550 |
19 | GW-8-5000/0.5J | 5000 | 950 (12 Pulse) |
3400 | 5000 | 4200 | 1250 | 7~8 | 500 | 3400 | 0.1~0.15 | 0.25~0.3 | 8 | 600/550 |
20 | GW-10-6000/0.5J | 6300 | 950 (12 Pulse) |
3750 | 6000 | 4600 | 1250 | 8.5~9 | 500 | 3400 | 0.1~0.15 | 0.25~0.3 | 10 | 600/550 |
21 | GW-12-8000/0.25J | 8000 | 950 (12 Pulse) |
4900 | 8000 | 6000 | 1250 | 9~10.5 | 250 | 3400 | 0.1~0.15 | 0.25~0.3 | 12 | 600-550 |
22 | GW-15-8000/0.25J | 8000 | 950 (12 Pulse) |
4900 | 8000 | 6000 | 1250 | 9~10.5 | 250 | 3400 | 0.1~0.15 | 0.25~0.3 | 15 | 600-550 |
23 | GW-15-10000/0.25J | 10000 | 950 (24 Pulse) |
6500 | 10000 | 8000 | 1250 | 13~15 | 250 | 3400 | 0.1~0.15 | 0.25~0.3 | 15 | 600-550 |
24 | GW-18-12000/0.25J | 12000 | 950 (24 Pulse) |
8160 | 12000 | 10000 | 1200 | 15~17 | 250 | 3400 | 0.1~0.15 | 0.25~0.3 | 18 | 600-550 |
25 | GW-20-12000/0.25J | 12000 | 950 (24 Pulse) |
8160 | 12000 | 10000 | 1200 | 17~19 | 250 | 3400 | 0.1~0.15 | 0.25~0.3 | 20 | 600-550 |
26 | GW-25-14000/0.25J | 14000 | 950 (24 Pulse) |
9460 | 14000 | 11600 | 1200 | 19~21 | 150~200 | 3400 | 0.1~0.15 | 0.25~0.3 | 25 | 600-550 |
27 | GW-30-16000/0.2J | 16000 | 950 (24 Pulse) |
10850 | 16000 | 13300 | 1200 | 21~23 | 150~200 | 3400 | 0.1~0.15 | 0.25~0.3 | 30 | 600-550 |
28 | GW-40-20000/0.2J | 20000 | 950 (24 Pulse) |
13545 | 20000 | 16600 | 1200 | 25~27 | 150~200 | 3400 | 0.1~0.15 | 0.25~0.3 | 40 | 600-550 |
29 | GW-50-22000/0.2J | 22000 | 950 (24 Pulse) |
14932 | 22000 | 18300 | 1200 | 25~28 | 150~200 | 3400 | 0.1~0.15 | 0.25~0.3 | 50 | 600-550 |
Note:
(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).
(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)
3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.
4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.
V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD.