Band Repair Clamp Material: Ductile Iron and Stainless steel 201 or 304 Coating: FBE coating Epoxy Bolts&Nuts: Galvanized Carbon Steel
Price : 9USD/set
The pipeline repairer can quickly repair the pipeline without stopping work. It is suitable for a variety of pipeline media and has a long service life. The pipeline repairer is strong and corrosion-resistant. It is an essential tool for pipeline repair.
The pipeline repairer solves the defect that the existing overall replacement and repair needs to cut off the internal flow of the pipeline, and also requires a large operating space, and includes the repair body. The repair body is divided into two layers, namely an outer layer and an inner layer, of which the outer layer is The outer layer is a flexible cladding layer, the inner layer is an elastic sealing layer, the outer layer and the inner layer are compounded, and the repair body deforms with the shape of the pipeline during cladding; a number of connecting holes are arranged on both sides of the outer layer , There is a covering part on the connecting hole, the covering part bypasses the outer wall of the pipeline and combines with the repair body to wrap and hold the pipeline. The outer layer is a force acting part, and the inner layer is a sealing part. When repairing, the inner layer is in contact with the outer wall of the pipeline. Fitting, the wrapping piece bypasses the pipeline and hugs the pipeline tightly, without cutting off the internal flow of the pipeline, and requires little operating space; the inner layer directly covers the cracks of the pipeline to prevent water from seeping out of the cracks
Induction furnace is used for smelting or insulating ferrous metals, non-ferrous metals, sponge iron, such as scrap iron, scrap steel, copper, aluminum and so on. Complete working equipment such as continuous casting machine, rolling mill, mainly used for the production of billet, steel bar, angle steel, H-beam, I-beam, etc. Using KGPS, IGBT, single or double power supply technology, PLC (Siemens) can be realized throughout the monitoring.
Main supply list: 2 sets of electric furnace body, 2 sets of hydraulic or mechanical tilting electric furnace mechanism, 1 set of control platform, 1 set of intermediate frequency control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), low voltage control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), 1 set of capacitor cabinet, 4 or 8 water-cooled cables; 1 water temperature alarm, 1 leakage alarm; 1 crucible mold, 1 liquid One batch of pressure steel pipe, one set of copper row, three water tanks. Transformer, cooling tower, furnace builder, furnace lining ejector, furnace cover.
KGSP Induction Electric Furnace
GW-8-4000-0.5J KGSP Induction Electric Furnace
GW-1-750-1JJ Medium frequency coreless electric furnace
GW-50-22000-0.2J No induction melting furnace
GW-0.25-160-1JJ melting electric furnace
GW-1.5-1000-1J Medium frequency induction furnace
NO. |
Electric
Furnace
Type |
Input
power
(KW) |
input
voltage
(V) |
Input
current
(A) |
Rated
power
(KW) |
DC
current
(A) |
DC
voltage
(V) |
Melting
rate
(T/H) |
working
frequency
(HZ) |
working
voltage
(V) |
cooling water
pressure(MPA) |
Rated
capacity
(T) |
Power
consumption
(KWH/T) |
Power
Supply |
Furnace
body |
1 |
GW-0.25-160/1JJ |
180 |
380
(6 Pulse) |
256 |
160 |
320 |
500 |
0.24 |
1000 |
750 |
0.1~0.15 |
0.25~0.3 |
0.25 |
790 |
2 |
GW-0.5-250/1JJ |
280 |
380
(6 Pulse) |
400 |
250 |
500 |
500 |
0.4 |
1000 |
1500 |
0.1~0.15 |
0.25~0.3 |
0.5 |
770 |
3 |
GW-0.5-250/1J |
280 |
380
(6 Pulse) |
400 |
250 |
500 |
500 |
0.4 |
1000 |
1500 |
0.1~0.15 |
0.25~0.3 |
0.5 |
770 |
4 |
GW-0.75-400/1JJ |
400 |
380
(6 Pulse) |
650 |
400 |
800 |
500 |
0.6 |
1000 |
1500 |
0.1~0.15 |
0.25~0.3 |
0.75 |
770 |
5 |
GW-0.75-400/1J |
400 |
380
(6 Pulse) |
650 |
400 |
800 |
500 |
0.6 |
1000 |
1500 |
0.1~0.15 |
0.25~0.3 |
0.75 |
770 |
6 |
GW-1-500/1JJ |
550 |
380
(6 Pulse) |
800 |
500 |
1000 |
500 |
0.8 |
1000 |
1500 |
0.1~0.15 |
0.25~0.3 |
1 |
750 |
7 |
GW-1-750/1JJ |
800 |
380/690
(6 Pulse) |
1200/
700 |
750 |
1500/
850 |
500/
880 |
0.9 |
1000/
500 |
1500/
2600 |
0.1~0.15 |
0.25~0.3 |
1 |
720/660 |
8 |
GW-1-750/1J |
800 |
380/690
(6 Pulse) |
1200/
700 |
750 |
1500/
850 |
500/
880 |
0.9 |
1000/
500 |
1500/
2600 |
0.1~0.15 |
0.25~0.3 |
1 |
720/660 |
9 |
GW-1.5-1000/0.5JJ |
1100 |
690
(6 Pulse) |
912 |
1000 |
1140 |
880 |
1.2 |
500 |
2600 |
0.1~0.15 |
0.25~0.3 |
1.5 |
700 |
10 |
GW-1.5-1000/0.5J |
1100 |
690
(6 Pulse) |
912 |
1000 |
1140 |
880 |
1.2 |
500 |
2600 |
0.1~0.15 |
0.25~0.3 |
1.5 |
700 |
11 |
GW-2-1500/0.5JJ |
1650 |
690
(6 Pulse) |
1360 |
1500 |
1700 |
880 |
1.7 |
500 |
2600 |
0.1~0.15 |
0.25~0.3 |
2 |
675 |
12 |
GW-2-1500/0.5J |
1650 |
690
(6 Pulse) |
1360 |
1500 |
1700 |
880 |
1.7 |
500 |
2600 |
0.1~0.15 |
0.25~0.3 |
2 |
675 |
13 |
GW-2-2000/0.5JJ |
2200 |
690
(6 Pulse) |
1400 |
2000 |
2275 |
880 |
1.9 |
500 |
2600 |
0.1~0.15 |
0.25~0.3 |
2 |
650 |
14 |
GW-3-2500/0.5JJ |
2750 |
690/950
(6 Pulse) |
2275/
1700 |
2500 |
2840/
2080 |
880/
1250 |
2.56 |
500 |
2600/3200 |
0.1~0.15 |
0.25~0.3 |
3 |
610/560 |
15 |
GW-3-2500/0.5J |
2750 |
690/950
(6 Pulse) |
2275/
1700 |
2500 |
2840/
2080 |
880/
1250 |
2.56 |
500 |
2600/3200 |
0.1~0.15 |
0.25~0.3 |
3 |
610/560 |
16 |
GW-4-3000/0.5J |
3300 |
690/950
(6 Pulse) |
2730/
2040 |
3000 |
3410/
2500 |
880/
1250 |
3.2 |
500 |
2600/3200 |
0.1~0.15 |
0.25~0.3 |
4 |
610/560 |
17 |
GW-5-4000/0.5J |
4400 |
950
(6 Pulse) |
2300 |
4000 |
3330 |
1250 |
5 |
500 |
3400 |
0.1~0.15 |
0.25~0.3 |
5 |
600/550 |
18 |
GW-6-4000/0.5J |
4400 |
950
(12 Pulse) |
2300 |
4000 |
3330 |
1250 |
5 |
500 |
3400 |
0.1~0.15 |
0.25~0.3 |
6 |
600/550 |
19 |
GW-8-5000/0.5J |
5000 |
950
(12 Pulse) |
3400 |
5000 |
4200 |
1250 |
7~8 |
500 |
3400 |
0.1~0.15 |
0.25~0.3 |
8 |
600/550 |
20 |
GW-10-6000/0.5J |
6300 |
950
(12 Pulse) |
3750 |
6000 |
4600 |
1250 |
8.5~9 |
500 |
3400 |
0.1~0.15 |
0.25~0.3 |
10 |
600/550 |
21 |
GW-12-8000/0.25J |
8000 |
950
(12 Pulse) |
4900 |
8000 |
6000 |
1250 |
9~10.5 |
250 |
3400 |
0.1~0.15 |
0.25~0.3 |
12 |
600-550 |
22 |
GW-15-8000/0.25J |
8000 |
950
(12 Pulse) |
4900 |
8000 |
6000 |
1250 |
9~10.5 |
250 |
3400 |
0.1~0.15 |
0.25~0.3 |
15 |
600-550 |
23 |
GW-15-10000/0.25J |
10000 |
950
(24 Pulse) |
6500 |
10000 |
8000 |
1250 |
13~15 |
250 |
3400 |
0.1~0.15 |
0.25~0.3 |
15 |
600-550 |
24 |
GW-18-12000/0.25J |
12000 |
950
(24 Pulse) |
8160 |
12000 |
10000 |
1200 |
15~17 |
250 |
3400 |
0.1~0.15 |
0.25~0.3 |
18 |
600-550 |
25 |
GW-20-12000/0.25J |
12000 |
950
(24 Pulse) |
8160 |
12000 |
10000 |
1200 |
17~19 |
250 |
3400 |
0.1~0.15 |
0.25~0.3 |
20 |
600-550 |
26 |
GW-25-14000/0.25J |
14000 |
950
(24 Pulse) |
9460 |
14000 |
11600 |
1200 |
19~21 |
150~200 |
3400 |
0.1~0.15 |
0.25~0.3 |
25 |
600-550 |
27 |
GW-30-16000/0.2J |
16000 |
950
(24 Pulse) |
10850 |
16000 |
13300 |
1200 |
21~23 |
150~200 |
3400 |
0.1~0.15 |
0.25~0.3 |
30 |
600-550 |
28 |
GW-40-20000/0.2J |
20000 |
950
(24 Pulse) |
13545 |
20000 |
16600 |
1200 |
25~27 |
150~200 |
3400 |
0.1~0.15 |
0.25~0.3 |
40 |
600-550 |
29 |
GW-50-22000/0.2J |
22000 |
950
(24 Pulse) |
14932 |
22000 |
18300 |
1200 |
25~28 |
150~200 |
3400 |
0.1~0.15 |
0.25~0.3 |
50 |
600-550 |
Note:
(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).
(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)
3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.
4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.
V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note:
(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).
(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)
3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.
4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.
V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD.
Induction furnace is used for smelting or insulating ferrous metals, non-ferrous metals, sponge iron, such as scrap iron, scrap steel, copper, aluminum and so on. Complete working equipment such as continuous casting machine, rolling mill, mainly used for the production of billet, steel bar, angle steel, H-beam, I-beam, etc. Using KGPS, IGBT, single or double power supply technology, PLC (Siemens) can be realized throughout the monitoring.
Main supply list: 2 sets of electric furnace body, 2 sets of hydraulic or mechanical tilting electric furnace mechanism, 1 set of control platform, 1 set of intermediate frequency control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), low voltage control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), 1 set of capacitor cabinet, 4 or 8 water-cooled cables; 1 water temperature alarm, 1 leakage alarm; 1 crucible mold, 1 liquid One batch of pressure steel pipe, one set of copper row, three water tanks. Transformer, cooling tower, furnace builder, furnace lining ejector, furnace cover.