3.75kw - 186kw Zzj Series DC Motor

Product Details
Customization: Available
Application: Industrial
Operating Speed: Adjust Speed
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Management System Certification
ISO 9001, ISO 14000
  • 3.75kw - 186kw Zzj Series DC Motor
  • 3.75kw - 186kw Zzj Series DC Motor
  • 3.75kw - 186kw Zzj Series DC Motor
  • 3.75kw - 186kw Zzj Series DC Motor
  • 3.75kw - 186kw Zzj Series DC Motor
  • 3.75kw - 186kw Zzj Series DC Motor
Find Similar Products

Basic Info.

Function
Control, Driving
Casing Protection
Protection Type
Number of Poles
4
Structure and Working Principle
Brushless
Type
Zjj
Brand
Semc
Name
Zzj Series DC Motor
Series
Zzj
Motor
DC
Power
3.75kw - 186kw
Voltage
220V/400V
Pole
2
Protection Level
: IP23/IP44
Cooling Method
IC01/IC06/IC17/IC37
Insulation Class
F
Transport Package
Plywood
Specification
3.75KW - 186KW ZZJ series DC motor 220V/400V 2 POL
Trademark
SEMC
Origin
Shanghai
Production Capacity
235

Packaging & Delivery

Package Size
23.00cm * 23.00cm * 23.00cm
Package Gross Weight
65.000kg

Product Description

3.75kw - 186kw Zzj Series DC Motor3.75kw - 186kw Zzj Series DC Motor3.75kw - 186kw Zzj Series DC Motor3.75kw - 186kw Zzj Series DC Motor3.75kw - 186kw Zzj Series DC Motor3.75kw - 186kw Zzj Series DC Motor3.75kw - 186kw Zzj Series DC Motor3.75kw - 186kw Zzj Series DC Motor

ZJJ Series DC Motor

 
Z Series Heavy duty Metallurgy DC Motor is newly developed products of our works. The products are found wide use for prime mover in various, such as mill auxiliary in metallurgical industry, metal cutting machine-tool, paper making, print, textile, printing and dyeing, cement-making, plastic extruding machine, etc.
Outline and mounting dimensions of the motors comply with IEC72 Standard, except for the axial distance between the mounting holes (dimension B).
Performance and technical requirements of the motors can be checked in accordance with IEC34-1 Standard of the International Electro technical Commission, or DIN57530 Norm of the Deutsche Industries-Norm.
The dc motors are class F insulated, with reliable insulating construction and impregnating process, ensuring stable dielectric performance and excellent heat dissipation.
The motors possess the features of small size, good performance, light weight, large output, high efficiency and reliability, being able to match the current international advanced level.

The motors can be lastingly operated form fully controlled three-phase bridge without a smoothing reactor. Motors for 160V may be operated on single-phase bridge thyristor. In that case, a smoothing reactor, whose inductance is specified in the relevant technical date, should be inserted in the armature circuit to suppress ripple current.

  • Performance
1. Data listed in the technical data sheet should be employed under the following conditions;
a. Altitude above sea level maximal 1,000m;
b. Cooling air temperature maximal 40oC;
c. Ambient conditions for motors should be free from acidic, alkali fumes or other aggressive gases which corrode insulation.

d. Duty: Continuous (SI);
e. Armature and field circuits for motors may be either operated on static thyrisier controlled supplies, or from d-c generator;
f. Performances of motors all comply with State Standard GB755.  Fundamental technical rules for electrical machines.
2. Standard rated voltage: 160V or 440V, Values for  220V, 400V, and 660V or other voltage may be derived on request.
3. Rated speed: 3000, 1500, 1000, 750, 600, 500, 400, 300 and 200 r/min, totally nine grades. Decrease armature voltage to make speed regulating under constant torque, lowering down field voltage to make speed regulating at constant output. Speed regulating range: see technical date. The torque can be remained constant by reducing speed via armature voltage weakening below raced value. It is stipulated that armature speed range can be down to the lowest 20 r/min at constant torque and stable running.
4. Separate excitation is the basic excitation type of the motors. Nominal field voltage: 180V.
Other excitation voltages are also acceptable on request. Forced excitation is allowed with the voltage of less than 500V. When a motor is normally running, its excitation current must not be higher than rated excitation current. To assure the reliability of insulation of excitation system, the motor must be protected against self induced voltages by a release resistor connected in parallel with the excitation circuit of the motor is  interrupted. At rated field voltage the value of shunt resistor is about seven times filed winding resistance (cold state). While the field voltage is higher than nominal voltage, the value of shunt resistance may be lower than seven times field resistance, otherwise higher than seven times.
5. For frame size Z4-315, Z4-355, Z4-400 and Z4-450, compensating windings are provided. For frame size Z4-250 and Z4-280 the motors are feasible with a compensating winding too.
6. A marked earthing terminal is provided forth motors.
7. The efficiencies listed in the date sheet are for rated output, voltage and speed, and include excitation lose, excluding that of separate ventilating fans.

1. The methods and defend class of the motor
a) The method of cooling of the motor is separately-cooled, according to the GB/T1993 "Method of cooling of rotating electrical machinery", there are IC06, IC17, IC37, IC86W. Standard entrance of cooling air is at the end of the main transmission (not the commutator side).The defend class of the motor can be divided into IP23 and IP44 according to the GB/T4942.1 "the crust defend class of rotating electrical machinery (IP code)". If the user needs other method of cooling and defend class, it can be negotiated.
b) The relation between the method of cooling and the defend class of the motor please see Table 1


3.75kw - 186kw Zzj Series DC Motor

3.75kw - 186kw Zzj Series DC Motor

2.The installation and the type of motor according to the GB/T997 "The structure and installation type of rotating electrical machinery", haveIM1001 (horizontal bottom install, column biaxial) and IM1002 (horizontal bottom install, column biaxial). If the user needs other kinds of installation structure, it must be negotiated.
3. The position of terminal box on standard motor is on the right side when seeing from the main drive end. It can also be installed on the left side, but it must be written in the order contact.
4. The motor using rolling bearing, nonstop adding oil structure.
5.The motor can be installed the following accessories at the user's option
a) Temperature detector component can be put into the stator winding and bearing room of two side, and connect the outlet wire to the terminal box.
b) The non-drive part of the machine can equipped with tachogenerator, centrifugal starting switch, coder and others which buildup the speed meter protecting device.
c) Heater for preventing condensation can be installed in the motor, but it must be written in the other contact.
6. The air-to-water heat exchanger is usually installed on the top of the motor. If the user wants it to be installed on the side of the motor, the user must put forward it when ordering and settle the assistant upholder by the user himself.
7.The cooler equipped with wind pressure switch, temperature controller, heater for preventing condensation and other protect device.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier