• Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor
  • Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor
  • Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor
  • Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor
  • Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor
  • Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor

Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor

Power: 200kW
Generator Type: DC Generator
Output Type: DC
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor pictures & photos
Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor
US $1,000,000 / Set
Min. Order: 1 Set
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
electric power generation motor
Certification
CCC, CE
Standard
Standard
Name
Sale Shanghai Electric Power Generation Motor Slot
Color
Green
Brand
Semc
machine
Power Generation Motor Slot
Type
Generation Motor Slot
Transport Package
Plywood
Trademark
SEMC
Origin
China
Production Capacity
500set/Year

Packaging & Delivery

Package Size
900.00cm * 800.00cm * 700.00cm
Package Gross Weight
500000.000kg

Product Description

Sale shanghai electric power generation motor slot wedges and stator or rotor 
Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor
Large-scale generators are one of the three major mainframes of modern power plants and belong to the core equipment of power plants. Damage to generators will cause huge economic losses to power plant production and operation, and even threaten the power supply security of the power grid in the core load area. Therefore, it is very important to ensure the safe and stable operation of large-scale generator sets, and the stator bars, which are the most important components of the generator, will be subjected to alternating magnetic field forces during operation. Due to the quiver of the iron core, the main insulation material will undergo slight thermal expansion and contraction. As a result, the wedges are seriously loosened and partially detached, which in turn exacerbates the vibration of the bar. The mechanical strength and dielectric properties of the main insulation tend to deteriorate. Long-term operation will lead to wear of the insulation layer, causing eddy currents and spark discharges, resulting in electric corrosion. Until the insulating layer breaks down, it eventually leads to a generator short-circuit accident and damage. Therefore, it is particularly important to periodically check the tightness of the stator wedge. During the overhaul period of our plant, we detected the tightness of the generator slot wedge after the rotor has been extracted as a key generator overhaul project. More than half of the slot wedges were found after the professional technicians together with the motor manufacturer technicians inspected the stator slot wedges. Below the Leeb hardness test standard. After consultation with power plant professionals, power plants, research institutes and power plants of the same type, the power plant professionals held a special seminar to determine the treatment opinions, scope, and plans.
        1 Stator slot wedge fixing structure
        The conventional slot fixing method of the generator factory is that after the stator bar is inserted into the stator slot, it is fastened with a pad strip and a slot wedge, as shown in FIG. 1 . This fixing method makes the slot wedge and the bar rigid. Contact, due to thermal expansion and contraction phenomenon and long-term operation of the insulation material such as a certain shrinkage, groove wedge will appear loose phenomenon

Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or RotorSale Shanghai Electric Power Generation Motor Slot Wedges and Stator or RotorSale Shanghai Electric Power Generation Motor Slot Wedges and Stator or RotorSale Shanghai Electric Power Generation Motor Slot Wedges and Stator or RotorSale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor
 


 

NO. Electric 
Furnace 
Type
Input 
power
(KW)
input 
voltage
(V)
Input 
current
(A)
Rated 
power
(KW)
DC 
current
(A)
DC 
voltage
(V)
Melting 
rate
(T/H)
working 
frequency
(HZ)
working 
voltage
(V)
cooling water
 pressure(MPA)
Rated 
capacity
(T)
Power 
consumption
(KWH/T)
Power 
Supply
Furnace 
body
1 GW-0.25-160/1JJ 180 380
(6 Pulse)
256 160 320 500 0.24 1000 750 0.1~0.15 0.25~0.3 0.25 790
2 GW-0.5-250/1JJ 280 380
(6 Pulse)
400 250 500 500 0.4 1000 1500 0.1~0.15 0.25~0.3 0.5 770
3 GW-0.5-250/1J 280 380
(6 Pulse)
400 250 500 500 0.4 1000 1500 0.1~0.15 0.25~0.3 0.5 770
4 GW-0.75-400/1JJ 400 380
(6 Pulse)
650 400 800 500 0.6 1000 1500 0.1~0.15 0.25~0.3 0.75 770
5 GW-0.75-400/1J 400 380
(6 Pulse)
650 400 800 500 0.6 1000 1500 0.1~0.15 0.25~0.3 0.75 770
6 GW-1-500/1JJ 550 380
(6 Pulse)
800 500 1000 500 0.8 1000 1500 0.1~0.15 0.25~0.3 1 750
7 GW-1-750/1JJ 800 380/690
(6 Pulse)
1200/
700
750 1500/
850
500/
880
0.9 1000/
500
1500/
2600
0.1~0.15 0.25~0.3 1 720/660
8 GW-1-750/1J 800 380/690
(6 Pulse)
1200/
700
750 1500/
850
500/
880
0.9 1000/
500
1500/
2600
0.1~0.15 0.25~0.3 1 720/660
9 GW-1.5-1000/0.5JJ 1100 690
(6 Pulse)
912 1000 1140 880 1.2 500 2600 0.1~0.15 0.25~0.3 1.5 700
10 GW-1.5-1000/0.5J 1100 690
(6 Pulse)
912 1000 1140 880 1.2 500 2600 0.1~0.15 0.25~0.3 1.5 700
11 GW-2-1500/0.5JJ 1650 690
(6 Pulse)
1360 1500 1700 880 1.7 500 2600 0.1~0.15 0.25~0.3 2 675
12 GW-2-1500/0.5J 1650 690
(6 Pulse)
1360 1500 1700 880 1.7 500 2600 0.1~0.15 0.25~0.3 2 675
13 GW-2-2000/0.5JJ 2200 690
(6 Pulse)
1400 2000 2275 880 1.9 500 2600 0.1~0.15 0.25~0.3 2 650
14 GW-3-2500/0.5JJ 2750 690/950
(6 Pulse)
2275/
1700
2500 2840/
2080
880/
1250
2.56 500 2600/3200 0.1~0.15 0.25~0.3 3 610/560
15 GW-3-2500/0.5J 2750 690/950
(6 Pulse)
2275/
1700
2500 2840/
2080
880/
1250
2.56 500 2600/3200 0.1~0.15 0.25~0.3 3 610/560
16 GW-4-3000/0.5J 3300 690/950
(6 Pulse)
2730/
2040
3000 3410/
2500
880/
1250
3.2 500 2600/3200 0.1~0.15 0.25~0.3 4 610/560
17 GW-5-4000/0.5J 4400 950
(6 Pulse)
2300 4000 3330 1250 5 500 3400 0.1~0.15 0.25~0.3 5 600/550
18 GW-6-4000/0.5J 4400 950
(12 Pulse)
2300 4000 3330 1250 5 500 3400 0.1~0.15 0.25~0.3 6 600/550
19 GW-8-5000/0.5J 5000 950
(12 Pulse)
3400 5000 4200 1250 7~8 500 3400 0.1~0.15 0.25~0.3 8 600/550
20 GW-10-6000/0.5J 6300 950
(12 Pulse)
3750 6000 4600 1250 8.5~9 500 3400 0.1~0.15 0.25~0.3 10 600/550
21 GW-12-8000/0.25J 8000 950
(12 Pulse)
4900 8000 6000 1250 9~10.5 250 3400 0.1~0.15 0.25~0.3 12 600-550
22 GW-15-8000/0.25J 8000 950
(12 Pulse)
4900 8000 6000 1250 9~10.5 250 3400 0.1~0.15 0.25~0.3 15 600-550
23 GW-15-10000/0.25J 10000 950
(24 Pulse)
6500 10000 8000 1250 13~15 250 3400 0.1~0.15 0.25~0.3 15 600-550
24 GW-18-12000/0.25J 12000 950
(24 Pulse)
8160 12000 10000 1200 15~17 250 3400 0.1~0.15 0.25~0.3 18 600-550
25 GW-20-12000/0.25J 12000 950
(24 Pulse)
8160 12000 10000 1200 17~19 250 3400 0.1~0.15 0.25~0.3 20 600-550
26 GW-25-14000/0.25J 14000 950
(24 Pulse)
9460 14000 11600 1200 19~21 150~200 3400 0.1~0.15 0.25~0.3 25 600-550
27 GW-30-16000/0.2J 16000 950
(24 Pulse)
10850 16000 13300 1200 21~23 150~200 3400 0.1~0.15 0.25~0.3 30 600-550
28 GW-40-20000/0.2J 20000 950
(24 Pulse)
13545 20000 16600 1200 25~27 150~200 3400 0.1~0.15 0.25~0.3 40 600-550
29 GW-50-22000/0.2J 22000 950
(24 Pulse)
14932 22000 18300 1200 25~28 150~200 3400 0.1~0.15 0.25~0.3 50 600-550


Note:
(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).

(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)

3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.

4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.

V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor pictures & photos
Sale Shanghai Electric Power Generation Motor Slot Wedges and Stator or Rotor
US $1,000,000 / Set
Min. Order: 1 Set
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
Registered Capital
5000000 RMB
Management System Certification
ISO 9001, ISO 14000