Max.Head: 110m-150m
Max.Capacity: 300-400 L/min
Driving Type: Magnetic
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump pictures & photos
Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump
US $1,000-5,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
fire pump
Material
Stainless Steel
Structure
Single-stage Pump
Assembly
Pipeline Pump
Power
Electric
Start Up
Electric Pump
Type
Positive-Displacement Pump
Application
Submersible Pump, Clarified Water Pump, Sewage Pump, Slurry Pump, Oil Transfer Pump, Chemical Pump
Industry
Fire Pump
Media
Sewage Pumps
Performance
Wear Pump
Theory
Centrifugal Pump
Product Name
Hy Constant Pressure Fire Pump Zw Self-Priming Fir
Brand
Semc
Pump
Pump Vertical Pipeline Fire Pump
system
Pump
Product Material
Fire
Transport Package
Plywood and Steel Frame
Specification
international standard
Trademark
semc
Origin
China
HS Code
8514300090
Production Capacity
500 Unit/Month

Packaging & Delivery

Package Size
600.00cm * 700.00cm * 600.00cm
Package Gross Weight
5000.000kg

Product Description

HY constant pressure fire pump ZW self-priming fire pump vertical Pipeline fire pump

Fire pump, as its name implies, is imported from abroad. According to different classification methods, it can be divided into different types, which are fully sealed, leak-free and corrosion-resistant. It is widely used in environmental protection, water treatment, fire protection and other departments. It is used to pump all kinds of liquids. It is an ideal pump and fire-fighting system for creating leak-free, pollution-free and civilized workshop and civilized factory. Yes. Pump types are similar, but the head and flow are different.

By use

1 powerless fire pump

Relying on the impeller rotation, the energy is transferred to the liquid without power source fire pump.

2 Vehicle Fire Pump

An unpowered fire pump mounted on the chassis of a fire engine.

3 Marine fire pump

Non-power fire pump installed in ship, offshore platform and working environment on water.

4 Fire Pump for Engineering

Fire pumps for fire hydrant systems, water sprinkler systems, foam extinguishing systems, etc.

5 Low Pressure Fire Pump

Fire pump with rated pressure less than 1.6 MPa.

6-Pressure Fire Pump

Fire pump with rated pressure ranging from 1.8 MPa to 3.0 MPa.

7 High Pressure Fire Pump

Fire pump with rated pressure not less than 4.0 MPa.

8 Medium and Low Pressure Fire Pump

It can provide both medium pressure and low pressure fire pump.

9 High and Low Pressure Fire Pump

It can provide both high pressure and low pressure fire pump.

10 Water Supply Fire Pump

Engineering fire pump for fire water supply.

11 Pressure stabilized fire pump

Engineering fire pump for stabilizing pressure of pipeline network.

12 foam pump

An engineering fire pump for transporting foam extinguishing agents. For example, in a balanced pressure foam proportioning device, a foam pump for transporting foam extinguishing agents is provided.

13 Deep Well Fire Pump

Engineering fire pump with vertical deep well pump.

14 diving fire pump

Engineering fire pump with submersible pump.

15 common fire pump

Engineering fire pump except deep well and submersible fire pump.
Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump
Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump

Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump
     Induction furnace is used for smelting or insulating ferrous metals, non-ferrous metals, sponge iron, such as scrap iron, scrap steel, copper, aluminum and so on. Complete working equipment such as continuous casting machine, rolling mill, mainly used for the production of billet, steel bar, angle steel, H-beam, I-beam, etc. Using KGPS, IGBT, single or double power supply technology, PLC (Siemens) can be realized throughout the monitoring.
 
       Main supply list: 2 sets of electric furnace body, 2 sets of hydraulic or mechanical tilting electric furnace mechanism, 1 set of control platform, 1 set of intermediate frequency control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), low voltage control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), 1 set of capacitor cabinet, 4 or 8 water-cooled cables; 1 water temperature alarm, 1 leakage alarm; 1 crucible mold, 1 liquid One batch of pressure steel pipe, one set of copper row, three water tanks. Transformer, cooling tower, furnace builder, furnace lining ejector, furnace cover.

KGSP Induction Electric Furnace
Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump

GW-8-4000-0.5J KGSP Induction Electric Furnace

Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump

GW-1-750-1JJ Medium frequency coreless electric furnace
Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump


GW-50-22000-0.2J No induction melting furnace
Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump

GW-0.25-160-1JJ melting electric furnace
Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump
GW-1.5-1000-1J Medium frequency induction furnace
Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump




 
NO. Electric 
Furnace 
Type
Input 
power
(KW)
input 
voltage
(V)
Input 
current
(A)
Rated 
power
(KW)
DC 
current
(A)
DC 
voltage
(V)
Melting 
rate
(T/H)
working 
frequency
(HZ)
working 
voltage
(V)
cooling water
 pressure(MPA)
Rated 
capacity
(T)
Power 
consumption
(KWH/T)
Power 
Supply
Furnace 
body
1 GW-0.25-160/1JJ 180 380
(6 Pulse)
256 160 320 500 0.24 1000 750 0.1~0.15 0.25~0.3 0.25 790
2 GW-0.5-250/1JJ 280 380
(6 Pulse)
400 250 500 500 0.4 1000 1500 0.1~0.15 0.25~0.3 0.5 770
3 GW-0.5-250/1J 280 380
(6 Pulse)
400 250 500 500 0.4 1000 1500 0.1~0.15 0.25~0.3 0.5 770
4 GW-0.75-400/1JJ 400 380
(6 Pulse)
650 400 800 500 0.6 1000 1500 0.1~0.15 0.25~0.3 0.75 770
5 GW-0.75-400/1J 400 380
(6 Pulse)
650 400 800 500 0.6 1000 1500 0.1~0.15 0.25~0.3 0.75 770
6 GW-1-500/1JJ 550 380
(6 Pulse)
800 500 1000 500 0.8 1000 1500 0.1~0.15 0.25~0.3 1 750
7 GW-1-750/1JJ 800 380/690
(6 Pulse)
1200/
700
750 1500/
850
500/
880
0.9 1000/
500
1500/
2600
0.1~0.15 0.25~0.3 1 720/660
8 GW-1-750/1J 800 380/690
(6 Pulse)
1200/
700
750 1500/
850
500/
880
0.9 1000/
500
1500/
2600
0.1~0.15 0.25~0.3 1 720/660
9 GW-1.5-1000/0.5JJ 1100 690
(6 Pulse)
912 1000 1140 880 1.2 500 2600 0.1~0.15 0.25~0.3 1.5 700
10 GW-1.5-1000/0.5J 1100 690
(6 Pulse)
912 1000 1140 880 1.2 500 2600 0.1~0.15 0.25~0.3 1.5 700
11 GW-2-1500/0.5JJ 1650 690
(6 Pulse)
1360 1500 1700 880 1.7 500 2600 0.1~0.15 0.25~0.3 2 675
12 GW-2-1500/0.5J 1650 690
(6 Pulse)
1360 1500 1700 880 1.7 500 2600 0.1~0.15 0.25~0.3 2 675
13 GW-2-2000/0.5JJ 2200 690
(6 Pulse)
1400 2000 2275 880 1.9 500 2600 0.1~0.15 0.25~0.3 2 650
14 GW-3-2500/0.5JJ 2750 690/950
(6 Pulse)
2275/
1700
2500 2840/
2080
880/
1250
2.56 500 2600/3200 0.1~0.15 0.25~0.3 3 610/560
15 GW-3-2500/0.5J 2750 690/950
(6 Pulse)
2275/
1700
2500 2840/
2080
880/
1250
2.56 500 2600/3200 0.1~0.15 0.25~0.3 3 610/560
16 GW-4-3000/0.5J 3300 690/950
(6 Pulse)
2730/
2040
3000 3410/
2500
880/
1250
3.2 500 2600/3200 0.1~0.15 0.25~0.3 4 610/560
17 GW-5-4000/0.5J 4400 950
(6 Pulse)
2300 4000 3330 1250 5 500 3400 0.1~0.15 0.25~0.3 5 600/550
18 GW-6-4000/0.5J 4400 950
(12 Pulse)
2300 4000 3330 1250 5 500 3400 0.1~0.15 0.25~0.3 6 600/550
19 GW-8-5000/0.5J 5000 950
(12 Pulse)
3400 5000 4200 1250 7~8 500 3400 0.1~0.15 0.25~0.3 8 600/550
20 GW-10-6000/0.5J 6300 950
(12 Pulse)
3750 6000 4600 1250 8.5~9 500 3400 0.1~0.15 0.25~0.3 10 600/550
21 GW-12-8000/0.25J 8000 950
(12 Pulse)
4900 8000 6000 1250 9~10.5 250 3400 0.1~0.15 0.25~0.3 12 600-550
22 GW-15-8000/0.25J 8000 950
(12 Pulse)
4900 8000 6000 1250 9~10.5 250 3400 0.1~0.15 0.25~0.3 15 600-550
23 GW-15-10000/0.25J 10000 950
(24 Pulse)
6500 10000 8000 1250 13~15 250 3400 0.1~0.15 0.25~0.3 15 600-550
24 GW-18-12000/0.25J 12000 950
(24 Pulse)
8160 12000 10000 1200 15~17 250 3400 0.1~0.15 0.25~0.3 18 600-550
25 GW-20-12000/0.25J 12000 950
(24 Pulse)
8160 12000 10000 1200 17~19 250 3400 0.1~0.15 0.25~0.3 20 600-550
26 GW-25-14000/0.25J 14000 950
(24 Pulse)
9460 14000 11600 1200 19~21 150~200 3400 0.1~0.15 0.25~0.3 25 600-550
27 GW-30-16000/0.2J 16000 950
(24 Pulse)
10850 16000 13300 1200 21~23 150~200 3400 0.1~0.15 0.25~0.3 30 600-550
28 GW-40-20000/0.2J 20000 950
(24 Pulse)
13545 20000 16600 1200 25~27 150~200 3400 0.1~0.15 0.25~0.3 40 600-550
29 GW-50-22000/0.2J 22000 950
(24 Pulse)
14932 22000 18300 1200 25~28 150~200 3400 0.1~0.15 0.25~0.3 50 600-550

Note:
(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).

(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)

3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.

4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.

V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump pictures & photos
Hy Constant Pressure Fire Pump Zw Self-Priming Fire Pump Vertical Pipeline Fire Pump
US $1,000-5,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
Registered Capital
5000000 RMB
Management System Certification
ISO 9001, ISO 14000