Product Details
Product Name |
Steam Turbine condenser parallel flow Turbine |
Type of output |
DC/AC Three Phase/AC Single Phase |
Generator type |
DC Generator/ Synchronous Generator |
Power |
100KW-2000KW |
A complete set of steam turbine island comprises of following equipments and sub-systems:
1.Turbine-generator set -
--power is generated through the action of generator driven by the turbine connected to it.
2.Water-condensation system
--steam is condensed to water to be circulated to boiler and heated again.
3.Vacuum system
A.sub-system of main steam (where steam circulates to propel the blades of turbine
)
B.water cycle system (where water circulates from condenser to be heated again
)
C.DCS system (monitors the operation of turbine and adjusts output rate
)
D. deaerating &water supplying system (where oxygen is removed to ensure good operation environment and water is supplied
)
4. Cooling Air system (for air-cooled unit only)
5. Generator system ( electricity is generated in this system)
Our protocol of delivering power plant construction project is as follow:
1.The Argumentation of Project
2. Engineering Design
a. Turbo-Gen Set and its auxiliary systems
b.Layout of Condensed Water System
c.Layout of Heat System
d.Civil Construction and Structure of Turbo-Gen Set
3.Equipment Purchase
a.Turbo Generator Set and its auxiliary systems
b.Condensed Water System
c.Vacuum System
d.Lower Temperature Heating System
4. Civil Construction
a.Foundation and the upper structure of the Turbo Generator House
b.Foundation of Turbo-Gen Set and its auxiliary systems
c.Foundation of other structures
5. Operation & Maintenance
a.Operation of power plant (technical counseling)
b.Regular maintenance and inspection
c.Technical Training Program for power plant personnel
d.General Overhaul
6. Installation & Testing
a.Installation & testing for all systems & equipment provided
b.Installation, testing & trail run of all systems of a power plant (Optional)
c.Installation, testing & trail run of entire power plant (Optional)
7. Supply of Spare Parts
Reference List
No. |
Item |
Project detail |
01 |
Commissioner |
LafargeHolcim |
Century Paper Mill |
Polat |
SPGCL |
02 |
Location |
Gombe State, Nigeria |
Lahore, Pakistan |
Turkey |
India |
03 |
Scope of service |
EPC project |
Engineering, Purchase, Supervision of construction |
EPC project |
EPC project |
04 |
Application |
service power plant
of a cement factory |
service power station of a paper mill |
independent power plant |
independent power plant |
05 |
Model |
air-cooled condensing
turbine island |
condensing/extracting turbine |
condensing turbine |
reheat turbine |
06 |
Brand |
Simons |
HTP |
HTP |
HTC |
07 |
Standard of engineering |
DIN. |
GB |
GB |
GB |
08 |
Layout |
single-story layout with horizontal steam discharge |
downward steam discharge |
downward steam discharge |
downward steam discharge |
09 |
Technical parameters |
presure of steam inlet:8.5MP
tem. of steam inlet: 435C.
rated power:16.5MW
back pressure:15KPa |
presure of steam inlet:4.9MP
tem. of steam inlet: 475C.
rated power:18MW
pressure of extraction:1.1MP
flow of extracted steam:54.6Mpa
back pressure:15KPa |
presure of steam inlet:8.83MP
tem. of steam inlet: 435C.
rated power:51MW
back pressure:4.9KPa |
presure of steam inlet:16.7MP
tem. of steam inlet: 538C.
rated power:300MW
pressure of extraction:1.1MP
back pressure:10KPa |
10 |
Performance (under standard condition) |
heat rate:2467kcal/kw
steam rate:4.16kg/kw |
heat rate:2206.5kcal/kw |
heat rate:2215.3kcal/kw
steam rate:4.16kg/kw |
steam rate:3.64kg/kw |
Product Description:
DC motor is a rotating motor that can convert DC electric energy into mechanical energy (DC motor) or mechanical energy into DC electric energy (DC generator). It is a motor that can convert DC and mechanical energy into one another. When it runs as a motor, it is a direct current motor, which converts electrical energy into mechanical energy; when it runs as a generator, it is a direct current generator, which converts mechanical energy into electrical energy.
Induction furnace is used for smelting or insulating ferrous metals, non-ferrous metals, sponge iron, such as scrap iron, scrap steel, copper, aluminum and so on. Complete working equipment such as continuous casting machine, rolling mill, mainly used for the production of billet, steel bar, angle steel, H-beam, I-beam, etc. Using KGPS, IGBT, single or double power supply technology, PLC (Siemens) can be realized throughout the monitoring.
Main supply list: 2 sets of electric furnace body, 2 sets of hydraulic or mechanical tilting electric furnace mechanism, 1 set of control platform, 1 set of intermediate frequency control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), low voltage control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), 1 set of capacitor cabinet, 4 or 8 water-cooled cables; 1 water temperature alarm, 1 leakage alarm; 1 crucible mold, 1 liquid One batch of pressure steel pipe, one set of copper row, three water tanks. Transformer, cooling tower, furnace builder, furnace lining ejector, furnace cover.
KGSP Induction Electric Furnace
GW-8-4000-0.5J KGSP Induction Electric Furnace
GW-1-750-1JJ Medium frequency coreless electric furnace
GW-50-22000-0.2J No induction melting furnace
GW-0.25-160-1JJ melting electric furnace
GW-1.5-1000-1J Medium frequency induction furnace
NO. |
Electric
Furnace
Type |
Input
power
(KW) |
input
voltage
(V) |
Input
current
(A) |
Rated
power
(KW) |
DC
current
(A) |
DC
voltage
(V) |
Melting
rate
(T/H) |
working
frequency
(HZ) |
working
voltage
(V) |
cooling water
pressure(MPA) |
Rated
capacity
(T) |
Power
consumption
(KWH/T) |
Power
Supply |
Furnace
body |
1 |
GW-0.25-160/1JJ |
180 |
380
(6 Pulse) |
256 |
160 |
320 |
500 |
0.24 |
1000 |
750 |
0.1~0.15 |
0.25~0.3 |
0.25 |
790 |
2 |
GW-0.5-250/1JJ |
280 |
380
(6 Pulse) |
400 |
250 |
500 |
500 |
0.4 |
1000 |
1500 |
0.1~0.15 |
0.25~0.3 |
0.5 |
770 |
3 |
GW-0.5-250/1J |
280 |
380
(6 Pulse) |
400 |
250 |
500 |
500 |
0.4 |
1000 |
1500 |
0.1~0.15 |
0.25~0.3 |
0.5 |
770 |
4 |
GW-0.75-400/1JJ |
400 |
380
(6 Pulse) |
650 |
400 |
800 |
500 |
0.6 |
1000 |
1500 |
0.1~0.15 |
0.25~0.3 |
0.75 |
770 |
5 |
GW-0.75-400/1J |
400 |
380
(6 Pulse) |
650 |
400 |
800 |
500 |
0.6 |
1000 |
1500 |
0.1~0.15 |
0.25~0.3 |
0.75 |
770 |
6 |
GW-1-500/1JJ |
550 |
380
(6 Pulse) |
800 |
500 |
1000 |
500 |
0.8 |
1000 |
1500 |
0.1~0.15 |
0.25~0.3 |
1 |
750 |
7 |
GW-1-750/1JJ |
800 |
380/690
(6 Pulse) |
1200/
700 |
750 |
1500/
850 |
500/
880 |
0.9 |
1000/
500 |
1500/
2600 |
0.1~0.15 |
0.25~0.3 |
1 |
720/660 |
8 |
GW-1-750/1J |
800 |
380/690
(6 Pulse) |
1200/
700 |
750 |
1500/
850 |
500/
880 |
0.9 |
1000/
500 |
1500/
2600 |
0.1~0.15 |
0.25~0.3 |
1 |
720/660 |
9 |
GW-1.5-1000/0.5JJ |
1100 |
690
(6 Pulse) |
912 |
1000 |
1140 |
880 |
1.2 |
500 |
2600 |
0.1~0.15 |
0.25~0.3 |
1.5 |
700 |
10 |
GW-1.5-1000/0.5J |
1100 |
690
(6 Pulse) |
912 |
1000 |
1140 |
880 |
1.2 |
500 |
2600 |
0.1~0.15 |
0.25~0.3 |
1.5 |
700 |
11 |
GW-2-1500/0.5JJ |
1650 |
690
(6 Pulse) |
1360 |
1500 |
1700 |
880 |
1.7 |
500 |
2600 |
0.1~0.15 |
0.25~0.3 |
2 |
675 |
12 |
GW-2-1500/0.5J |
1650 |
690
(6 Pulse) |
1360 |
1500 |
1700 |
880 |
1.7 |
500 |
2600 |
0.1~0.15 |
0.25~0.3 |
2 |
675 |
13 |
GW-2-2000/0.5JJ |
2200 |
690
(6 Pulse) |
1400 |
2000 |
2275 |
880 |
1.9 |
500 |
2600 |
0.1~0.15 |
0.25~0.3 |
2 |
650 |
14 |
GW-3-2500/0.5JJ |
2750 |
690/950
(6 Pulse) |
2275/
1700 |
2500 |
2840/
2080 |
880/
1250 |
2.56 |
500 |
2600/3200 |
0.1~0.15 |
0.25~0.3 |
3 |
610/560 |
15 |
GW-3-2500/0.5J |
2750 |
690/950
(6 Pulse) |
2275/
1700 |
2500 |
2840/
2080 |
880/
1250 |
2.56 |
500 |
2600/3200 |
0.1~0.15 |
0.25~0.3 |
3 |
610/560 |
16 |
GW-4-3000/0.5J |
3300 |
690/950
(6 Pulse) |
2730/
2040 |
3000 |
3410/
2500 |
880/
1250 |
3.2 |
500 |
2600/3200 |
0.1~0.15 |
0.25~0.3 |
4 |
610/560 |
17 |
GW-5-4000/0.5J |
4400 |
950
(6 Pulse) |
2300 |
4000 |
3330 |
1250 |
5 |
500 |
3400 |
0.1~0.15 |
0.25~0.3 |
5 |
600/550 |
18 |
GW-6-4000/0.5J |
4400 |
950
(12 Pulse) |
2300 |
4000 |
3330 |
1250 |
5 |
500 |
3400 |
0.1~0.15 |
0.25~0.3 |
6 |
600/550 |
19 |
GW-8-5000/0.5J |
5000 |
950
(12 Pulse) |
3400 |
5000 |
4200 |
1250 |
7~8 |
500 |
3400 |
0.1~0.15 |
0.25~0.3 |
8 |
600/550 |
20 |
GW-10-6000/0.5J |
6300 |
950
(12 Pulse) |
3750 |
6000 |
4600 |
1250 |
8.5~9 |
500 |
3400 |
0.1~0.15 |
0.25~0.3 |
10 |
600/550 |
21 |
GW-12-8000/0.25J |
8000 |
950
(12 Pulse) |
4900 |
8000 |
6000 |
1250 |
9~10.5 |
250 |
3400 |
0.1~0.15 |
0.25~0.3 |
12 |
600-550 |
22 |
GW-15-8000/0.25J |
8000 |
950
(12 Pulse) |
4900 |
8000 |
6000 |
1250 |
9~10.5 |
250 |
3400 |
0.1~0.15 |
0.25~0.3 |
15 |
600-550 |
23 |
GW-15-10000/0.25J |
10000 |
950
(24 Pulse) |
6500 |
10000 |
8000 |
1250 |
13~15 |
250 |
3400 |
0.1~0.15 |
0.25~0.3 |
15 |
600-550 |
24 |
GW-18-12000/0.25J |
12000 |
950
(24 Pulse) |
8160 |
12000 |
10000 |
1200 |
15~17 |
250 |
3400 |
0.1~0.15 |
0.25~0.3 |
18 |
600-550 |
25 |
GW-20-12000/0.25J |
12000 |
950
(24 Pulse) |
8160 |
12000 |
10000 |
1200 |
17~19 |
250 |
3400 |
0.1~0.15 |
0.25~0.3 |
20 |
600-550 |
26 |
GW-25-14000/0.25J |
14000 |
950
(24 Pulse) |
9460 |
14000 |
11600 |
1200 |
19~21 |
150~200 |
3400 |
0.1~0.15 |
0.25~0.3 |
25 |
600-550 |
27 |
GW-30-16000/0.2J |
16000 |
950
(24 Pulse) |
10850 |
16000 |
13300 |
1200 |
21~23 |
150~200 |
3400 |
0.1~0.15 |
0.25~0.3 |
30 |
600-550 |
28 |
GW-40-20000/0.2J |
20000 |
950
(24 Pulse) |
13545 |
20000 |
16600 |
1200 |
25~27 |
150~200 |
3400 |
0.1~0.15 |
0.25~0.3 |
40 |
600-550 |
29 |
GW-50-22000/0.2J |
22000 |
950
(24 Pulse) |
14932 |
22000 |
18300 |
1200 |
25~28 |
150~200 |
3400 |
0.1~0.15 |
0.25~0.3 |
50 |
600-550 |
Note:
(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).
(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)
3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.
4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.
V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|