• 185kw to 2500kw Eplosion Proof AC Motor
  • 185kw to 2500kw Eplosion Proof AC Motor
  • 185kw to 2500kw Eplosion Proof AC Motor
  • 185kw to 2500kw Eplosion Proof AC Motor
  • 185kw to 2500kw Eplosion Proof AC Motor
  • 185kw to 2500kw Eplosion Proof AC Motor

185kw to 2500kw Eplosion Proof AC Motor

Application: Industrial
Speed: High Speed
Number of Stator: Three-Phase
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
185kw to 2500kw Eplosion Proof AC Motor pictures & photos
185kw to 2500kw Eplosion Proof AC Motor
US $22,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
YRKS
Function
Control
Casing Protection
Closed Type
Number of Poles
4
Starting Mode
Variable Frequency Starting
Certification
ISO9001
Brand
Semc
Color
Blue
Rpm
High
Pols
4
Orignal Brand
Semc
Consmption Power
185kw to 2500kw
Name
185kw to 2500kw Eplosion Proof AC Motor
Type
AC
Machine
Motor
System
Eplosion Proof
Transport Package
Pllywood
Specification
frame size: 143T-449T, 230-690V
Trademark
SEMC
Origin
China
HS Code
85011020
Production Capacity
3000/Year

Packaging & Delivery

Package Size
500.00cm * 700.00cm * 600.00cm
Package Gross Weight
5000.000kg

Product Description

What Is an Explosion-Proof Motor?

There are two scenarios in which an electric motor can cause an explosion:

  1. The surface temperature of the electric motor increases due to heating that occurs to match the ignition temperature of the flammable matter that has accumulated in the factory or the industrial structure, causing a spontaneous explosion.

  2. The electric motor sparks as a result of an anomaly that causes an explosion within the casing. This explosion becomes the catalyst that ignites the incendiary dust or liquid in the factory, resulting in a bigger explosion.

An electric motor is considered explosion-proof when it is capable of containing an internal explosion without rupturing and putting the entire industrial facility at risk.

Though the terms "explosion-proof motor" and "hazardous location motor" are often used interchangeably, there are key differences that become evident once the divisions and classes of operating spaces are carefully analyzed.

Types of Hazardous Locations and Groups of Inflammable Materials

Division: Location

  • Division I - A Division I location is hazardous even in normal conditions. Flammable particulate matter or incendiary liquids are produced, and they accumulate as a result of the execution of manufacturing processes.

  • Division II - A Division II location becomes hazardous in abnormal conditions. If there is a rupture, burst, or leak resulting in spillage or seepage of inflammable substances, then the area is considered a Division II property.

Class: Location

  • Class I - Class I locations contain gases and vapors that are known to auto-ignite and cause explosions. Gasoline and acetylene are common examples of such vapors.

  • Class II - Class II locations involve the presence of flammable dust, like grain and coal, in the environment.

  • Class III - Class III locations involve the presence of flammable fibers, such as textile and wood shavings.

Groups: Type of Principal Flammable Agent

  • Groups A to D - Acetylene, hydrogen, ethylene, and acetone are some of the gases and vapors that belong to these groups.

  • Groups E to G - Covering aluminum, coal, corn, and sugar, these groups only pertain to flammable particulate matter.

Classifications and Standards for Hazardous Location Motors: A Five-Step Selection Guide

Choosing the right hazardous location motor can be a daunting task. But the following guidelines can help users zero in on the specific type of motor construction they need to ensure the safety of their property and location.

  1. Identify the division and class of your property. Local safety authorities can usually assist in this process.

  2. If you are a Division I, Class I location, you need a proper explosion-proof electric motor. It should be fully capable of confining the effects of an internal explosion, as the slightest exposure to sparks can auto-ignite the flammable vapors in the atmosphere. Motors with tighter joints and longer flame paths cool escaping flames, allowing them to be extinguished.

  3. If you are a Division I, Class II location, it's a good idea to choose an electric motor with a casing that keeps the surface relatively cool. These motors have bearing dust seals.

  4. It is more important to identify the class of your location, as opposed to the division. By default, all Division I equipment will also serve Division II requirements. Motors that serve Division II locations are generally referred to as hazardous location motors - motors that can handle anomalous hazardous situations.

  5. UL is the only safety agency recognized for the approval of motors in hazardous locations. However, this body doesn't offer any evaluation standards for:

  • Motors that can run in Division I, Class I, Groups A and B locations

  • Motors that run in Division II locations

  • Motors that run in Class III locations

A vendor claiming UL approval for such equipment shouldn't be trusted.

The Importance of Motor Classifications

Knowing the division, class, and group of your property is crucial for ensuring you choose a well-suited motor that will improve productivity without introducing the danger of explosions. Likewise, fully understanding the hazardous location and explosion-proof motor standards will greatly reduce the risk of accidents and injuries.

More cautious users may also explore the auto-ignition temperatures of their flammables and put in place cooling systems or ventilation machines, which keep heating in check and prevent the buildup of incendiary material in enclosed spaces.185kw to 2500kw Eplosion Proof AC Motor185kw to 2500kw Eplosion Proof AC Motor

nduction furnace is used for smelting or insulating ferrous metals, non-ferrous metals, sponge iron, such as scrap iron, scrap steel, copper, aluminum and so on. Complete working equipment such as continuous casting machine, rolling mill, mainly used for the production of billet, steel bar, angle steel, H-beam, I-beam, etc. Using KGPS, IGBT, single or double power supply technology, PLC (Siemens) can be realized throughout the monitoring.
 
       Main supply list: 2 sets of electric furnace body, 2 sets of hydraulic or mechanical tilting electric furnace mechanism, 1 set of control platform, 1 set of intermediate frequency control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), low voltage control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), 1 set of capacitor cabinet, 4 or 8 water-cooled cables; 1 water temperature alarm, 1 leakage alarm; 1 crucible mold, 1 liquid One batch of pressure steel pipe, one set of copper row, three water tanks. Transformer, cooling tower, furnace builder, furnace lining ejector, furnace cover.


 
     Induction furnace is used for smelting or insulating ferrous metals, non-ferrous metals, sponge iron, such as scrap iron, scrap steel, copper, aluminum and so on. Complete working equipment such as continuous casting machine, rolling mill, mainly used for the production of billet, steel bar, angle steel, H-beam, I-beam, etc. Using KGPS, IGBT, single or double power supply technology, PLC (Siemens) can be realized throughout the monitoring.
 
       Main supply list: 2 sets of electric furnace body, 2 sets of hydraulic or mechanical tilting electric furnace mechanism, 1 set of control platform, 1 set of intermediate frequency control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), low voltage control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), 1 set of capacitor cabinet, 4 or 8 water-cooled cables; 1 water temperature alarm, 1 leakage alarm; 1 crucible mold, 1 liquid One batch of pressure steel pipe, one set of copper row, three water tanks. Transformer, cooling tower, furnace builder, furnace lining ejector, furnace cover.

KGSP Induction Electric Furnace
185kw to 2500kw Eplosion Proof AC Motor

GW-8-4000-0.5J KGSP Induction Electric Furnace

185kw to 2500kw Eplosion Proof AC Motor

GW-1-750-1JJ Medium frequency coreless electric furnace
185kw to 2500kw Eplosion Proof AC Motor


GW-50-22000-0.2J No induction melting furnace
185kw to 2500kw Eplosion Proof AC Motor

GW-0.25-160-1JJ melting electric furnace
185kw to 2500kw Eplosion Proof AC Motor
GW-1.5-1000-1J Medium frequency induction furnace
185kw to 2500kw Eplosion Proof AC Motor




 
NO. Electric 
Furnace 
Type
Input 
power
(KW)
input 
voltage
(V)
Input 
current
(A)
Rated 
power
(KW)
DC 
current
(A)
DC 
voltage
(V)
Melting 
rate
(T/H)
working 
frequency
(HZ)
working 
voltage
(V)
cooling water
 pressure(MPA)
Rated 
capacity
(T)
Power 
consumption
(KWH/T)
Power 
Supply
Furnace 
body
1 GW-0.25-160/1JJ 180 380
(6 Pulse)
256 160 320 500 0.24 1000 750 0.1~0.15 0.25~0.3 0.25 790
2 GW-0.5-250/1JJ 280 380
(6 Pulse)
400 250 500 500 0.4 1000 1500 0.1~0.15 0.25~0.3 0.5 770
3 GW-0.5-250/1J 280 380
(6 Pulse)
400 250 500 500 0.4 1000 1500 0.1~0.15 0.25~0.3 0.5 770
4 GW-0.75-400/1JJ 400 380
(6 Pulse)
650 400 800 500 0.6 1000 1500 0.1~0.15 0.25~0.3 0.75 770
5 GW-0.75-400/1J 400 380
(6 Pulse)
650 400 800 500 0.6 1000 1500 0.1~0.15 0.25~0.3 0.75 770
6 GW-1-500/1JJ 550 380
(6 Pulse)
800 500 1000 500 0.8 1000 1500 0.1~0.15 0.25~0.3 1 750
7 GW-1-750/1JJ 800 380/690
(6 Pulse)
1200/
700
750 1500/
850
500/
880
0.9 1000/
500
1500/
2600
0.1~0.15 0.25~0.3 1 720/660
8 GW-1-750/1J 800 380/690
(6 Pulse)
1200/
700
750 1500/
850
500/
880
0.9 1000/
500
1500/
2600
0.1~0.15 0.25~0.3 1 720/660
9 GW-1.5-1000/0.5JJ 1100 690
(6 Pulse)
912 1000 1140 880 1.2 500 2600 0.1~0.15 0.25~0.3 1.5 700
10 GW-1.5-1000/0.5J 1100 690
(6 Pulse)
912 1000 1140 880 1.2 500 2600 0.1~0.15 0.25~0.3 1.5 700
11 GW-2-1500/0.5JJ 1650 690
(6 Pulse)
1360 1500 1700 880 1.7 500 2600 0.1~0.15 0.25~0.3 2 675
12 GW-2-1500/0.5J 1650 690
(6 Pulse)
1360 1500 1700 880 1.7 500 2600 0.1~0.15 0.25~0.3 2 675
13 GW-2-2000/0.5JJ 2200 690
(6 Pulse)
1400 2000 2275 880 1.9 500 2600 0.1~0.15 0.25~0.3 2 650
14 GW-3-2500/0.5JJ 2750 690/950
(6 Pulse)
2275/
1700
2500 2840/
2080
880/
1250
2.56 500 2600/3200 0.1~0.15 0.25~0.3 3 610/560
15 GW-3-2500/0.5J 2750 690/950
(6 Pulse)
2275/
1700
2500 2840/
2080
880/
1250
2.56 500 2600/3200 0.1~0.15 0.25~0.3 3 610/560
16 GW-4-3000/0.5J 3300 690/950
(6 Pulse)
2730/
2040
3000 3410/
2500
880/
1250
3.2 500 2600/3200 0.1~0.15 0.25~0.3 4 610/560
17 GW-5-4000/0.5J 4400 950
(6 Pulse)
2300 4000 3330 1250 5 500 3400 0.1~0.15 0.25~0.3 5 600/550
18 GW-6-4000/0.5J 4400 950
(12 Pulse)
2300 4000 3330 1250 5 500 3400 0.1~0.15 0.25~0.3 6 600/550
19 GW-8-5000/0.5J 5000 950
(12 Pulse)
3400 5000 4200 1250 7~8 500 3400 0.1~0.15 0.25~0.3 8 600/550
20 GW-10-6000/0.5J 6300 950
(12 Pulse)
3750 6000 4600 1250 8.5~9 500 3400 0.1~0.15 0.25~0.3 10 600/550
21 GW-12-8000/0.25J 8000 950
(12 Pulse)
4900 8000 6000 1250 9~10.5 250 3400 0.1~0.15 0.25~0.3 12 600-550
22 GW-15-8000/0.25J 8000 950
(12 Pulse)
4900 8000 6000 1250 9~10.5 250 3400 0.1~0.15 0.25~0.3 15 600-550
23 GW-15-10000/0.25J 10000 950
(24 Pulse)
6500 10000 8000 1250 13~15 250 3400 0.1~0.15 0.25~0.3 15 600-550
24 GW-18-12000/0.25J 12000 950
(24 Pulse)
8160 12000 10000 1200 15~17 250 3400 0.1~0.15 0.25~0.3 18 600-550
25 GW-20-12000/0.25J 12000 950
(24 Pulse)
8160 12000 10000 1200 17~19 250 3400 0.1~0.15 0.25~0.3 20 600-550
26 GW-25-14000/0.25J 14000 950
(24 Pulse)
9460 14000 11600 1200 19~21 150~200 3400 0.1~0.15 0.25~0.3 25 600-550
27 GW-30-16000/0.2J 16000 950
(24 Pulse)
10850 16000 13300 1200 21~23 150~200 3400 0.1~0.15 0.25~0.3 30 600-550
28 GW-40-20000/0.2J 20000 950
(24 Pulse)
13545 20000 16600 1200 25~27 150~200 3400 0.1~0.15 0.25~0.3 40 600-550
29 GW-50-22000/0.2J 22000 950
(24 Pulse)
14932 22000 18300 1200 25~28 150~200 3400 0.1~0.15 0.25~0.3 50 600-550

Note:
(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).

(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)

3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.

4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.

V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD.
                         
   
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             
                             

Note:
(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).

(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)

3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.

4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.

V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
185kw to 2500kw Eplosion Proof AC Motor pictures & photos
185kw to 2500kw Eplosion Proof AC Motor
US $22,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
Registered Capital
5000000 RMB
Management System Certification
ISO 9001, ISO 14000